Search results for "Isotope dilution"
showing 10 items of 48 documents
International descriptive and interventional survey for oxycholesterol determination by gas- and liquid-chromatographic methods
2018
International audience; Increasing numbers of laboratories develop new methods based on gas-liquid and high-performance liquid chromatography to determine serum concentrations of oxygenated cholesterol metabolites such as 7alpha-, 24(S)-, and 27-hydroxycholesterol. We initiated a first international descriptive oxycholesterol (OCS) survey in 2013 and a second interventional survey 2014 in order to compare levels of OCS reported by different laboratories and to define possible sources of analytical errors. In 2013 a set of two lyophilized serum pools (A and B) was sent to nine laboratories in different countries for OCS measurement utilizing their own standard stock solutions. In 2014 eleven…
Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…
2000
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…
Internal exposure of the general population to DEHP and other phthalates--determination of secondary and primary phthalate monoester metabolites in u…
2003
A number of phthalates and their metabolites are suspected of having teratogenic and endocrine disrupting effects. Especially the developmental and reproductive effects of di(2-ethylhexyl)phthalate (DEHP) are under scrutiny. In this study we determined the concentrations of the secondary, chain oxidized monoester metabolites of DEHP, mono(2-ethyl-5-hydroxyhexyl)phthalate (5OH-MEHP) and mono(2-ethyl-5-oxo-hexyl)phthalate (5oxo-MEHP) in urine samples from the general population. The utilization of the secondary metabolites minimized any risk of contamination by the ubiquitously present phthalate parent compounds. Included in the method were also the simple monoester metabolites of DEHP, dioct…
Inverse correlation between plasma oxysterol and LDL-cholesterol levels in hepatitis C virus-infected patients
2012
Background: Hepatitis C virus infection is characterised by enhanced oxidative stress, which can be measured quantitatively by plasma oxysterol concentration. These molecules may affect lipid metabolism through the activation of Liver X Receptors. Hepatitis C virus exploits host lipid metabolism to facilitate its replication and diffusion. In our study we aimed to evaluate and highlight the potential pathogenetic role of oxysterols, 7-ketocholesterol and 7-β-hydroxycholesterol, in hepatitis C virus-related lipid dysmetabolism. Methods: The study was performed in 42 patients with chronic hepatitis C (93% genotype 1b) and 38 non-alcoholic fatty liver disease patients. Plasma oxysterols 7-keto…
Gel Electrophoresis Coupled to Inductively Coupled Plasma−Mass Spectrometry Using Species-Specific Isotope Dilution for Iodide and Iodate Determinati…
2007
In this paper, we present an online coupling of gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of iodine species (iodide and iodate) in liquid (seawater) and aerosol samples. For the first time, this approach is applied to the analysis of small molecules, and initial systematic investigations revealed that the migration behavior as well as the detection sensitivity strongly depends on the matrix (e.g., high concentrations of chloride). These effects could consequently affect the accuracy of analytical results, so that they need to be considered for the analysis of real samples. The technique used for quantification is species-specifi…
Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MS
2003
The applicability of the isotope dilution (ID) technique for trace element determinations in powdered solid samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is demonstrated. LA-ICP-IDMS combines the advantage of the isotope dilution technique as a definitive method with the powerful capability of LA-ICP-MS for a fast and direct multi-element analysis of solid samples. LA-ICP-IDMS therefore allows matrix-matched quantification of element concentrations without any external standard, which is not possible by other calibration strategies used in LA-ICP-MS, up to now. The sample preparation effort is kept minimal and consists of an addition of the corresponding…
Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.
2017
A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8 μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology.
Ageing of Dissolved Halogenated Humic Substances and the Microbiological Influence on this Process
2000
The distribution of halogens in various fractions of humic substances (HS), separated by their molecular weight, was found to be different for the different halogens. This was demonstrated for chlorine, bromine, and iodine in sewage and brown water samples by applying inductively coupled plasma mass spectrometry coupled with size-exclusion chromatography. Quantification of the different fractions of iodinated humic substances was obtained by quadrupole mass spectrometry in connection with the isotope dilution technique using an 129I-enriched spike solution. Quantitative analysis was not possible for the corresponding chlorine and bromine species because of spectrometric interferences in the…
Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS
2005
Abstract Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark™-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3–3 was observed when changing the nebulizer gas flow rate in the range of 0.84–1.0 L min−1 and the laser power density in the range of 2–10 GW cm−2, respectively. When using an internal…